  • 380V DC Power: Shaping the Future of Data Center Energy ...

    Jun 25, 2015· 380V DC Power: Shaping the Future of Data Center Energy Efficiency Deploying DC power distribution in the data center instead of using the traditional AC design is one way to reduce power loss, eliminate unnecessary conversions and, ultimately, lower energy costs. Industry Perspectives |

  • a question about 460V/60Hz motor run on 380V/50Hz power ...

    Apr 03, 2017· When the VFD is set to run the motor at 1190 RPM the VFD will be outputting 380 Volts at 50 Hz. Motor performance should be equal at either 460 Volts/60 Hz and 380 Volts/50 Hz, up to 50 Hz. Above 50 Hz the torque will start to fall off. Maximum torque is

  • 380 V Primary Three Phase Control Transformers

    380 V Primary Three Phase Control Transformers TEMCo's three phase control transformers are copper wound and built with heat-proof insulation for compact size and long life. Wiring is made easy by the solidly fixed terminals with standard combination slotted Robertson head screw connections.

  • Whats the Most Cost-Effective Way to Obtain 380V? | EC&M

    Oct 01, 1998· A large textile plant purchased several looms from Europe, which operate on 380V, 3-phase. The only distribution voltage available is 480V, 3-phase. The plant requested advice on the most economical way to obtain 380V for these loads. The electrical service to these looms is from a

  • 380 V electric motors manufacturer

    380 V 3 phase asynchronous motors from German manufacturer and supplier MENZEL are used in industrial plants all over the world. Whether the cement plant in South America, the water industry in North Africa or the steelworks in Europe - MENZEL 380V motors are manufactured for particularly tough and extreme industrial requirements and applications.

  • 380 Volt in the US - Home - Practical Machinist

    Apr 22, 2018· 380 at 50 Hz is same V/Hz as 460 at 60 Hz. So you can just "plug it in" as long as you can use 60 Hz, which runs it at 6/5 speed, The machine will work fine at 440/460-60Hz. Everything will run 20% faster, so you may wish to change a motor pulley.

  • 208 to 380 Volt? | Mike Holt's Forum

    Jun 20, 2010· So yes, you can supply it with 380 volts, and use it to supply equipment rated for 380 volts. I would tend to want to verify that the equipment really is rated for 380. I recently completed a project for an overseas facility for which the distribution system was 220 volts phase to neutral, 380 volts phase to phase, and 60 hertz.

  • 380 volt transformer, 380 volt transformer Suppliers and ...

    1,705 380 volt transformer products are offered for sale by suppliers on Alibaba, of which transformers accounts for 4%. A wide variety of 380 volt transformer options are available to you, such as power, electronic, and lighting. You can also choose from three, single 380 volt transformer, as well as from toroidal 380 volt transformer, and ...

  • flaisli wheel chancador

    flaisli wheel chancador; , informacion tecnica planos chancador chancador gator ficha tecnica mapa del sitio Chancadores de piedra,picadora de piedra en Chile. More Price. produsen ball grinding made in usa. stone crusher produsen made in italy - bluegrassmdus stone crusher produsen made in italy LM Vertical Grinding appl; 1 9 produsen crusher ...

  • What is the difference between 220 volts, 3 phase and 380 ...

    Between each hot wire, 380 volts can be measured. Between the neutral and any of the hot wires, 220 volts can be measured. The kiln circuits are connected to the neutral line and one of the hot lines for each kiln section to provide 220 volts for each kiln section.